What wavelength for reading COD test? (Read 245 times)
remember0505
YaBB Newbies
*
Offline

I love Water and
Wastewater.com

Posts: 24
Ho Chi Minh City
Gender: male

Company or Organization: VITTEP
What wavelength for reading COD test?
Jul 22nd, 2011, 12:57am
 
Hi everybody!
I'm testing for COD by Standard Method 5220D. I'm using HACH DR890 to measure the absorbance but it's not support in 600nm, it's only support in 610nm.
Can i measure the absorbance of sample in 610nm?
Excuse for my english skill!!
Thanks for help! Smiley
Back to top
 
 
  IP Logged
David S.
Senior Member
****
Offline

I have nothing
clever to say here.

Posts: 373

Gender: male

Company or Organization: Environmental Express
Re: What wavelength for reading COD test?
Reply #1 - Jul 22nd, 2011, 9:44am
 
The method says that you should use 600.  Now, I've run different methods with a slightly different wavelength and been able to get good results.  I would try it at 610 and see if you can get acceptable QC.  If it passes and anyone ever asks why you do 610 instead of 600, tell them you had to optimize the wavelength for your instrument's performance.
Back to top
 
 

Working hard to bring reason to the field of regulation.
WWW   IP Logged
H2O_Tech
Junior Member
**
Offline

Water and
Wastewater.com is
the best!

Posts: 86

Re: What wavelength for reading COD test?
Reply #2 - Jul 22nd, 2011, 11:33am
 
The DR890 has four, fixed wavelengths (420/520/560/610 nm).  The program you enter (17 for COD, High range and high range+) selects the proper wavelength (in this case, 610), and the internal curve is used to determine what conc.

You can always verify with standards to be sure that a 100 mg/L reads as 100 mg/L (or whatever conc matters to you).
Back to top
 
 
  IP Logged