measurement of dissolved oxygen in testing process (Read 316 times)
Cooke RC
YaBB Newbies
*
Offline

I love Water and
Wastewater.com

Posts: 6


Company or Organization: Fortrans Inc.
measurement of dissolved oxygen in testing process
Aug 24th, 2011, 10:38am
 
I am testing a new method of increasing DO in water.
I am using a YSI DO meter. When I run compressed air through our
system I get 8.29 ppm DO and 97% saturation.
When we run oxygen the levels are out of range of the YSI meter (20 ppm).
The winkler method is only good up to 10 ppm. any suggestions?
Back to top
 
 
  IP Logged
BarfingCat
YaBB Newbies
*
Offline

Water and
Wastewater.com is
the best!

Posts: 34
Independence, MO
Gender: male

Company or Organization: Little Blue Valley Sewer Dist.
Re: measurement of dissolved oxygen in testing process
Reply #1 - Aug 29th, 2011, 5:02pm
 
Not to Sound like a salesman, but Hach LDO range is 0.1 to 20.0 mg/l.
Back to top
 
 
  IP Logged
Jim Royer
Junior Member
**
Offline

I love Water and
Wastewater.com

Posts: 95


Company or Organization: Urbana Champaign SD
Re: measurement of dissolved oxygen in testing process
Reply #2 - Sep 12th, 2011, 3:18pm
 
The Winkler will work. Just titrate a smaller aliquot of sample. DO meters will read up to 20 mg/L.
Back to top
 
 
  IP Logged
Cooke RC
YaBB Newbies
*
Offline

I love Water and
Wastewater.com

Posts: 6


Company or Organization: Fortrans Inc.
Re: measurement of dissolved oxygen in testing process
Reply #3 - Sep 13th, 2011, 8:32am
 
Thank you. We will try that.