Home
W&WW Blog Case Histories Books Shop Amazon  Member Survey Advertise
Buyer's Guide News Help Forum Ask Tom! Jobs Videos Newsletters

Search

Directory Links

  Plant Directory Home
  Search Plants
  New Plant Listings
  Random Listings
  Add Your Plant
  Modify Plant Listing
  Login

More Links

  Industry Directory
 
Plants Directory
 
Video Center
 
This Week's Newsletter
 
Water Blog
 
Ask Tom! Archive
 
Trade Shows & Events
 
Industry Associations
 
Journals & Magazines
 
Tank Size Calculators
 
Add Your Plant Now
 
Add Your Company
 
Add Your Resume
 
Contact Us

Sign Up Free!

Click here to read past issues
"Read by over 7,700 Industry
Professionals each week."


Enter your business email
address & click to sign up
Read Past Issues Here

Featured Book
From
Amazon

Click here for more

Free Shipping
on all orders over $25.

 

 

Water and Wastewater Plant Directory
L
Click here now
Wicklow, Ireland, Ireland
Coolmoney Camp
County Wicklow,Ireland
Wicklow, Ireland
Ireland

Contact Information:
Contact:  David Fay
Email:  dfay@fayenvcanada.com
Telephone:  709 738 1252
Fax:  709 754 4183

Plant Operation: Commercial

Processing: Water

Web site:
http://www.fayenvcanada.com

Plant/Process Description:
Project Profile Coolmoney Camp, Co. Wicklow

Client: Department of Defense Infirmary Road, Dublin 7. Consulting Engineers: Ryan Hanley – Victor van der Walt. Daily Demand: 250 m³/day Build, design and operate: 100%

Raw Water Intake & Pumping through a Rough bar screen Mild steel galvanized construction with 12MM spacings c/w hand rake and inlet air life pump. A 500-micron rotating drum screen c/w gear- drive motor, spray bar washing system and overflow channel and debris chute. Duty standby vertical multistage centrifugal pumps, suction & delivery gate valves with swing check valves, pressure indicators and level control protection.

Prefiltration using a GRP bodied multimedia filter with raw water quality monitoring using Continuous on-line pH and turbidity monitoring and recording.

System flow and Control measurement using in line magnetic flow meter complete with the downstream flow control butterfly valve, measurement and totalisation of all flows.

Ozone generation and air preparation using a low frequency, Corona discharge type water-cooled ozone generator complete with motive water pumps, non return and isolation valves, pressure indicator and gas injector. In line mixer, off gas thermal scrubber and cooling water supply. Screw type air compressor sets in acoustic enclosed with galvanized air receiver vessel, complete with all necessary pipework valves and instrumentation including ORP and pH meter.

Stainless steel ozone reactor vessel with channel ozone leak gas detector and alarm system.

Treated water and filtrate monitoring and recording with flow, pH and turbidity.

Filter washing with backwash connection to rising main complete with the necessary pipe work, valves and fittings. Air scour blowers acoustic enclosures, pressure relief valve’s non- return check and isolation valves, fittings and pressure indicators.

Electrical control equipment located on the inside a form 4 mild steel logstrup control panel.

Automatic power factor correction equipment such as the MCB’s starter, overloads and relays to control electric motors, hours run meters, fault and run lamps, hand off auto snap switches and duty selector switches and mounted in the door face. S.C.A.D.A. (SYSTEM CONTROL AND DATA ACQUISITION) Complete system to allow for monitoring and control of the treatment works at remote location. System supplied with touch sensitive screen PC for interfacing with the system and modem links to allow communication with the system and PLC. Allowance is also made for access to the system from clients offices. Advanced pc operating systems Windows NT or 2000PE. SCADA software National Instruments Lookout.

Supplementary disinfections using FE Biochlor on site electrolytic hypochlorite generation and dosing systems. Comprising of salt saturator, water softener, electrolyser, make-up tank and a product storage tank, Duty and standby metering pumps with residual feedback controller as well as residual analysers, one entering the reservoir and the second exiting the reservoir.

Reservoir link comprising of a 4 Channel radio to communicate with the plant to monitoring the treated water outflow to supply, chlorine residual value and reservoir level. All data transmitted by the radio will be logged by the SCADA system and used for control purpose where required. Reservoir level is used to stop and start the treatment plant.

Building and civil works included: Excavation of site Connection to rising main Inlet sump & intake structure Roadway Plant-house building Steel Frame construction with block-work infill white dashed rendered externally. Fair face block internal finish painted and neatly pointed. Slated Roof (Synthetic) Plant hose RC slab Building services including WC, shower, heating and lighting Boundary fencing approx 100 linear metres Landscaping, gravelling, kerbing, planting and weed-proof barrier.

Owner:
Department of Defense
Web site:  http://
Operating Company:
Fay Environmental
Web site:  http://www.fayenv.com
Directions:

x
Plant Directory HomeSearch PlantsNew Plant ListingsRandom Listings
Add Your PlantModify Plant ListingLogin

 
 
 
Disclaimer:  Water and Wastewater.com provides the information on this page for reference purposes only. We do not certify the accuracy of the information provided by third-party individuals for this listing.
 
 
 
I

Buyers Guide | News | Help Forum | Ask Tom! Column | Jobs | Resumes | Newsletters

W&WW Blog | Case Histories | Books | Shop Amazon | Member Survey | Advertise

.

Copyright © 1998-2008 Camber Southeast, Inc.
Web Site:  http://www.waterandwastewater.com
Privacy Statement

I
Home