Home
W&WW Blog Case Histories Books Shop Amazon  Member Survey Advertise
Buyer's Guide News Help Forum Ask Tom! Jobs Videos Newsletters

Search

News Center Links

 News Center Home

  Industry News
  Case Histories
  Air Quality
  Chemicals
  Coatings
  Controls
  Conveying
  Dewatering
  Piping
  Pumping
  Software
  Systems
  Tanks
  Valves
  Water Supply
  Wastewater

More Links

  Industry Directory
 
Plants Directory
 
Video Center
 
This Week's Newsletter
 
Water Blog
 
Ask Tom! Archive
 
Trade Shows & Events
 
Industry Associations
 
Journals & Magazines
 
Tank Size Calculators
 
Add Your Plant Now
 
Add Your Company
 
Add Your Resume
 
Contact Us

Sign Up Free!

Click here to read past issues
Industry Newsletter

Enter your business email
address & click to sign up
Read Past Issues Here

Featured Book
From
Amazon

Click here for more

Free Shipping
on all orders over $25.

 
 
Case Histories : Wastewater


Case Study : City of Sanford, Florida
By Kate Koerber
Jun 5, 2008
  E-mail article
Printer friendly page
  .
Sanford, FL -- In order to meet the demand of growth within the city and to achieve stringent effluent limits, the City of Sanford worked with CPH Engineers to design the Sanford South Water Resource Center (WRC), located in the heart of Central Florida. The facility produces a high quality effluent, as well as reclaimed water, which is distributed throughout the region. The plant is a 2.0 MGD “Advanced Secondary plus Filtration Facility.” The plant is easily expandable to 6.0 MGD plus tertiary treatment.

Plant Overview

The Sanford South WRC consists of 2.0 MGD primary, secondary, and tertiary treatment. The primary treatment includes automatic, continuous self-cleaning mechanical barscreens (1 mm), a screening compacting/dewatering screw system, multi-directional wet scrubber system, flow metering systems, and a “vortex-type” grit removal system.

Secondary treatment is comprised of a Kruger Bio-Denitro system which consists of a dual ditch system followed by final clarifiers and RAS/WAS pumping systems.

Tertiary treatment consists of Kruger Hydrotech Discfilters, chemical feed systems, and high level disinfection (“bulk” NaOCl).

Treatment of the biosolids includes a sludge holding tank, sludge dewatering system, and Class A biosolids production using an “indirect” sludge drying system, odor control system, and storage silo.

Process Solution

To answer the challenge, the Project Manager, Benjamin Fries of CPH Engineers and the City, evaluated numerous biological nutrient removal (BNR) and tertiary treatment technologies for the Sanford project. Mr. Fries and the City’s team determined Kruger’s Bio-Denitro and Hydrotech Discfilter combination to be the most cost effective and energy efficient system to meet the City’s effluent limits of cBOD less than 10 mg/L, TSS less than 5 mg/L, TN less than 8 mg/L, and a maximum month NH3-N less than 1 mg/L.

The Bio-Denitro system consists of one (1) influent distributor, two (2) automated effluent weirs, two (2) 7.4 HP submersible mixers, and four (4) 60 HP brush aerators. The Bio-Denitro system uses a Phased Isolation Ditch (PID) technology that alternates between aerobic (for nitrification) and anoxic (for denitrification) phases. The phases work by separating aeration and mixing in the different ditches, as well as incorporating automated dissolved oxygen (DO) control.

The Kruger Hydrotech Discfilter system consists of two (2) HSF2212-2F Discfilter units, installed below ground in concrete basins, for tertiary treatment to meet the plant’s TSS effluent requirements. The Discfilters use filter media panels mounted onto vertical disc segments for a small footprint, easy to operate solution.

Charlie Turner, Sanford South WRC Utility Plants Manager, stated, “The City of Sanford is pleased with our new plant and the Kruger treatment process. This was my first new wastewater plant startup and to tell you the truth I was not sure what to expect. I can tell you that I was surprised and extremely pleased when we were able to generate reclaimed water quality effluent on the fifth day after initial startup! Our initial regulatory compliance inspection was performed in July, our fourth month of operation. The inspection was successful with no deficiencies indicated on the follow up report. This demonstrates the effectiveness of the Kruger process! I appreciate the support given by Kruger staff at start up and during the shake down period.”

Conclusion

The effectiveness of Kruger’s Bio-Denitro system, followed by the Kruger Hydrotech Discfilter, has allowed the Sanford South WRC to produce a high quality effluent for their reclaimed water that is distributed to a reclaim water disposal site, two golf courses, as well as residents and businesses around the area for irrigation.

For more information contact:
Kruger Inc.
401 Harrison Oaks Blvd.
Suite 100
Cary, NC 27513
Telephone: 919.677.8310
Fax: 919.677.0082
Email: krugerincmarketing@veoliawater.com
Web site: http://www.krugerusa.com/


© Copyright 1998 - 2008 Water and Wastewater.com

Top of Page

 
Send news and case histories to:  news@waterandwastewater.com
 
 

 

I Search News I



I Live Newsfeed I

Increase traffic and add
content to your website
with our exclusive
newsfeed generator.

Our live newsfeed
allows you to
include news
headlines from our
News Center, right
on your homepage.

Headlines update in
real-time, automatically.

Click here to create
your own newsfeed!

 

 

 
 
I

Buyers Guide | News | Help Forum | Ask Tom! Column | Jobs | Resumes | Newsletters

W&WW Blog | Case Histories | Books | Shop Amazon | Member Survey | Advertise

.

Copyright © 1998-2008 Camber Southeast, Inc.
Web Site:  http://www.waterandwastewater.com
Privacy Statement

I
Home